Pumps, valves and heat exchangers for data center cooling

Hydraulic components for cloud, colocation, AI, HPC and mining data centers: chillers, free cooling, facility water systems, CDUs, immersion cooling and heat recovery. KSB and Ebara pumps with VFDs, balancing valves, plate heat exchangers. Technical selection, stock available, worldwide shipping.

Why data centers need more pumps

Cloud, artificial intelligence, high performance computing and mining keep pushing up power per rack. A latest-generation AI server rack dissipates around 130 kW. Air cooling in practice handles 20-40 kW per rack: above that threshold heat has to be removed with water. Every new AI hall adds hydraulic loops, redundant pumps, heat exchangers and valves.

Italy expects EUR 25 billion of data center investment in 2026-2028, with 83 new projects and 75% of capacity concentrated in the Milan area (Data Center Observatory, Politecnico di Milano, July 2026). Over the same period the liquid cooling component supply chain is working with long lead times.

Roffia supplies the hydraulic package wherever the site is: pumps, valves, heat exchangers, fittings and accessories from a single supplier, with technical selection and stock for urgent site requirements.

Every type of data center

Size and density vary, but the hydraulics are the same: water or glycol to circulate, heat to reject, uptime to guarantee.

Data center types and their cooling systems
Type Typical cooling What is needed
Hyperscale and cloud Chillers with free cooling, chilled water, increasingly direct-to-chip liquid cooling Large pumps in N+1, motorised butterfly valves, plate heat exchangers, grooved fittings
Colocation Chilled water to CRAHs and rear doors, AI halls with CDUs Twin inline pumps, PICV balancing, control valves, phased expansions
AI and HPC (high performance computing, supercomputing) Direct-to-chip liquid cooling with CDUs, facility water at 30-45 °C Pumps with VFDs, plate heat exchangers, strainers, sensors, components for CDU manufacturers
Mining farms (cryptocurrency, blockchain) Immersion cooling in dielectric fluid or water-cooled hydro-miners, dry coolers Pumps and plate heat exchangers on the water loop between tanks and dry coolers, valves, fittings, joints
Edge and enterprise data centers Compact chillers, in-row units, free cooling Pumps and circulators, balancing valves, expansion vessels, accessories
Heat recovery Heat pumps supplying district heating, greenhouses, industrial processes Large plate heat exchangers, circulation pumps, control valves

The three loops of a liquid-cooled data center

Heat travels from the racks to the outside through three water loops in series, separated by heat exchangers. Each loop has its own pumps and valves.

Diagram of data center cooling loops: heat rejection, facility water, technology cooling system, racks 1 · Heat rejection — chillers, dry coolers, cooling towers End-suction / split case pumps with VFDs · butterfly valves · check valves · strainers · joints plate heat exchanger (free cooling) 2 · Facility water system (FWS) — 30-45 °C Inline and twin pumps · PICV balancing · 2/3-way control valves · grooved fittings CDU: heat exchanger + N+1 pumps 3 · Technology cooling system (TCS) — treated water or PG25 glycol 304/316L stainless steel · fine strainers · motorised valves · sensors AI racks up to 130 kW: cold plates on GPUs and CPUs
Arrows follow the heat. Shaded in blue: loops where Roffia supplies pumps and valves directly; on the technology cooling system we supply components to CDU manufacturers.
Components by data center cooling loop and brands supplied by Roffia
Loop Where Components Brands
1. Heat rejection Chillers, dry coolers, cooling towers, free cooling End-suction and split case pumps with VFDs (N+1), motorised butterfly valves, dual plate check valves, Y-strainers, anti-vibration joints, expansion joints, plate heat exchangers for free cooling KSB, Ebara, Valbia, Italvalvole, Alfa Laval, Swep
2. Facility water system (FWS) Distribution loop to CRAHs, rear doors, CDUs · 30-45 °C with direct liquid cooling Single and twin inline pumps with differential pressure control, pressure independent control valves (PICV), 2/3-way control valves, isolation ball valves, grooved fittings, expansion vessels, deaerators, dirt separators KSB, Caleffi, Danfoss, Siemens, RM
3. Technology cooling system (TCS) From the CDU to the racks · treated water or propylene glycol PG25 Components for CDU manufacturers: stainless steel plate heat exchangers, motorised control valves, fine strainers, pressure and temperature sensors. 304/316L stainless steel, EPDM seals Danfoss, Samson, Siemens, Valvoinox
Heat recovery Heat pumps and district heating supplied with data center waste heat Large plate heat exchangers, circulation pumps, control valves, instrumentation KSB, Alfa Laval, Swep, Danfoss
Utilities Make-up water, water treatment, fire protection Stainless steel multistage pumps for pressure boosting, dosing pumps for chemical treatment, UNI EN 12845 fire pump sets KSB, Ebara, Etatron

Products for data center cooling

Who we work with

Chiller, CDU and IT cooling unit manufacturers
Pumps, heat exchangers, valves and instrumentation for series production, with scheduled deliveries and stock for urgent needs.
Mechanical contractors and installers
The complete hydraulic package for the site, delivered in phases, with the documentation required for commissioning.
Distributors and traders abroad
Branded pumps and valves from Italian stock when local channels are stretched. Quotations in English and French, documents for resale.
Data center operators and maintenance teams
Original KSB and Ebara spare parts, mechanical seals, replacement valves and joints, with short lead times.

Why Roffia

  • Worldwide shipping: Europe, the Middle East, Africa, the Americas and Asia. Quotations in English, French and Italian, delivery terms and export documents per Incoterms.
  • Stock available: valves, fittings, joints, spare parts and standard pumps ready to ship when manufacturers quote long lead times.
  • One supplier for the whole package: pumps, heat exchangers, valves, fittings and accessories from more than 25 brands.
  • Technical selection with official KSB and Ebara software, plate heat exchanger sizing.
  • Full documentation: datasheets, curves, CE and PED declarations, EN 10204 3.1 certificates where applicable.
  • Since 1968 in industrial plant: water, steam, thermal oil, compressed air.

What to include in your enquiry

Components and quantities, current make and model or acceptable alternatives

Pump duty point: flow (m³/h) and head (m)

Fluid and temperature: water, glycol (%), chilled or condenser water

Motor: rating, voltage and frequency, IE class, VFD

Materials and connections: cast iron or stainless steel, PN or ANSI flanges

Destination and timing: country, Incoterms, delivery date

Partial data is fine: for fast-track projects we call you back to complete the selection.

Email vendite@roffia.com with this template

Frequently asked questions

Which pumps are used to cool a data center?
It depends on the loop. On the heat rejection loop (chillers, dry coolers, cooling towers) large-capacity end-suction or split case pumps are used. On the facility water system single or twin vertical inline pumps are used. On the technology cooling system serving the racks the pump sits inside the CDU and is usually stainless steel. In every case the pumps run on variable frequency drives with N+1 or 2N redundancy. Roffia selects and supplies KSB and Ebara pumps: see data center cooling pumps.
Why do AI data centers use liquid cooling?
A latest-generation AI server rack (e.g. NVIDIA GB300 NVL72) dissipates around 130 kW, while air cooling in practice handles 20-40 kW per rack. Above that threshold heat has to be removed with water: cold plates on the processors, CDUs and dedicated hydraulic loops. Every MW of AI white space therefore needs more pumps, heat exchangers and valves than a conventional data center.
What is a CDU and does Roffia supply them?
A CDU (Coolant Distribution Unit) separates the facility water system from the loop that feeds the racks. It contains a plate heat exchanger, redundant pumps, strainers, control valves and sensors. Roffia does not build CDUs; we supply components to the companies that do: pumps, plate heat exchangers, control valves, strainers and instrumentation.
Which valves are used in data center cooling systems?
Wafer or lug butterfly valves with electric actuators for isolation on large diameters; pressure independent control valves (PICV) to distribute flow between CRAHs, rear door heat exchangers and CDUs; 2-way and 3-way control valves; dual plate check valves on pump discharges; stainless steel ball valves for branch connections; automatic air vents.
Does Roffia export data center components outside Italy?
Yes. Roffia ships worldwide: Europe, the Middle East, Africa, the Americas and Asia. We work with contractors, chiller and CDU manufacturers, distributors and traders abroad. Quotations are issued in English and French, EXW/FCA Cremona or delivered on request, with full documentation (datasheets, curves, CE declarations, EN 10204 3.1 certificates where applicable).
How quickly can Roffia deliver pumps and valves to a data center site?
Stock items (valves, fittings, expansion joints, spare parts, standard pumps) ship within a few days to any country. For large pumps or special configurations the quotation states the delivery date confirmed by the manufacturer. Liquid cooling components are in short supply: for fast-track projects, send us your enquiry as early as possible, even with partial data.
What information do you need for a quotation?
Component type and quantities, current make and model or acceptable alternatives, pump duty point (flow in m³/h and head in m), fluid and temperature (water or glycol, percentage), motor rating and VFD, materials and connections (PN or ANSI), destination country, required delivery date and documents needed. Use the RFQ template.

Working on a data center project?

Send us the component list or the system schematic. We select pumps, valves and heat exchangers and send you a quotation with confirmed delivery dates.