Data center cooling pumps
KSB and Ebara inline, end-suction, split case and multistage pumps with VFDs, selected on the duty point and configured for N+1 or 2N redundancy. For chiller, free cooling, facility water, heat recovery and fire protection loops.
Request a pump quotationThe right pump for each loop
A liquid-cooled data center has several loops in series: heat rejection, facility water and the technology cooling system serving the racks (see the full diagram on the data center sector page). Each loop uses pumps of a different type and size, always with VFDs and always with a standby.
We select the pump with official KSB and Ebara software on the actual duty point, including the effect of glycol on viscosity and absorbed power, and propose the matching drive.
| Pump type | Where it is used | Series | Why |
|---|---|---|---|
| Vertical inline, single or twin | Facility water system, secondary distribution | KSB Etaline | Small footprint, mounted directly in the pipework. A twin pump provides redundancy in a single casing. |
| End-suction to EN 733 | Chiller, condenser and free cooling loops | KSB Etanorm, Ebara | Baseplate-mounted, easy back pull-out maintenance, wide choice of impellers. |
| Close-coupled | Secondary loops, air handling units, heat recovery | KSB Etabloc, Ebara | Motor and pump on a common shaft: compact, fewer alignment issues. |
| Split case (axially split) | Primary loop on large campuses, condenser water | KSB, on selection | High flows at high efficiency; inspection without removing the pipework. |
| Vertical multistage, stainless steel | Pressure boosting, make-up water, water treatment, reverse osmosis | KSB Movitec, Ebara EVMS / EVMSG | High heads in a small footprint, stainless steel hydraulics. |
| Fire pump sets | Data center sprinkler and hydrant systems | KSB, Ebara | UNI EN 12845 compliant, with electric and diesel drivers. |
Availability and lead time for each series confirmed in the quotation.
Redundancy
N+1 with single pumps in parallel, 2N with separate lines, or twin inline pumps with a changeover valve. Check and isolation valves on every pump allow maintenance without shutting down the loop.
Efficiency
High-efficiency motors (up to IE5 with KSB SuPremE) and VFDs with differential pressure control. Absorbed power falls with the cube of speed: the most direct lever on the plant's PUE.
Fluid and materials
Cast iron for chiller and facility water loops, stainless steel for water treatment and loops serving the CDUs. Mechanical seals and elastomers compatible with glycol mixtures (PG25).
The rest of the hydraulic package
Every pump needs the same components around it. We supply them in the same quotation:
- Butterfly valves for isolation, including motorised
- Dual plate check valves
- Y-type strainers on suction
- Anti-vibration joints on suction and discharge
- Static balancing valves and PICV
- Plate heat exchangers for free cooling and CDUs
- Pressure gauges, thermometers, expansion vessels
Worldwide delivery and spare parts
- Worldwide shipping, quotations in English, French and Italian, delivery per Incoterms.
- Stock for standard pumps, spare parts and accessories: dispatch within a few days.
- Large pumps: delivery date confirmed by the manufacturer stated in the quotation.
- Documents: datasheets, curves, CE declarations, test certificates and EN 10204 3.1 where applicable.
- Original spare parts from KSB and Ebara: impellers, mechanical seals, bearings.
What to include in your pump enquiry
Pump type and quantity, or make and model to be replaced
Flow (m³/h) and head (m)
Fluid: water or glycol (%), temperature
Motor: kW, voltage and frequency, IE class, VFD
Redundancy: N+1, 2N, twin pump
Destination, Incoterms and delivery date
Frequently asked questions
Which pumps are used in data centers?
What do N+1 and 2N redundancy mean for pumps?
Why do data center pumps run on VFDs?
Can the pumps handle glycol mixtures?
Does Roffia supply KSB and Ebara data center pumps for export?
Do you supply spare parts for pumps already installed in the data center?
Pumps for a data center?
Send us the duty point or the project pump schedule. We reply with the KSB or Ebara selection, the drive and the delivery dates.