ATEX valves for classified zones

Industrial valves for potentially explosive environments (ATEX Directive 2014/34/EU): trunnion ball valves fire-safe API 607, anti-static BS 5146/ISO 7121, bellow-sealed, PED safety valves. For oil & gas, hydrogen, biogas, chemical-pharmaceutical. Ribel, Spirax Sarco, GESTRA brands.

Safety in explosive atmosphere: the responsibility of valves

The ATEX 2014/34/EU directive is the European regulatory framework governing equipment and systems for use in potentially explosive atmospheres: gases, vapors, mists and dusts that, mixed with air, can lead to explosions if ignited. The directive applies to all industrial sectors with flammable substances: oil & gas, refining, hydrogen, ammonia, biogas, chemical, distilleries, painting, mills, waste management.

Valves are mechanical components and generally do not require ATEX marking (they do not produce active ignition sources), but must still be compatible with zone classification: fire-safe API 607 construction to resist external flame, anti-static BS 5146 / ISO 7121 device to prevent electrostatic sparks, materials suitable for the fluid and service pressure. Electrical accessories (actuators, limit switches, sensors, positioners) however require complete ATEX marking with appropriate protection code for the zone (II 2G Ex db IIC T6 for Zone 1 hydrogen, II 3G Ex for Zone 2, etc.).

Roffia distributes industrial valves for ATEX classified zones with complete dossier for HSE, INAIL audits and third-party inspections. The range covers all types: trunnion-mounted fire-safe ball valves, PED category III/IV safety valves, bellow seal valves for zero emissions, butterfly, check, ESD emergency shutdown valves.

ATEX zone classification

Zone Atmosphere Frequency Accessory marking
Zone 0Gas/vaporsPermanent or frequentII 1G — Category 1G (maximum protection)
Zone 1Gas/vaporsLikely in normal activityII 2G — Ex db, Ex eb, Ex ib
Zone 2Gas/vaporsUnlikely or briefII 3G — Ex nA, Ex nC
Zone 20DustsPermanent or frequentII 1D
Zone 21DustsLikelyII 2D
Zone 22DustsUnlikely or briefII 3D

Valve types for ATEX applications

Application sectors

Domande frequenti

What is the ATEX directive and when does it apply to valves?
The ATEX 2014/34/EU directive (Atmosphères Explosibles) regulates equipment intended for use in potentially explosive atmospheres: environments where flammable gases, vapors, mists or dusts can create explosive mixtures with air. The ATEX 1999/92/EC directive (employer side) classifies hazardous areas in zones: Zone 0 (permanent or frequent presence of explosive atmosphere, e.g. tank interior), Zone 1 (likely during normal activity, e.g. sampling points), Zone 2 (unlikely or short duration, e.g. plant perimeter). Valves are purely mechanical components generally not subject to ATEX marking (they do not produce active ignition sources); however associated accessories such as limit switches, position sensors, electric actuators, positioners must be ATEX certified appropriate to the zone (II 2G Ex for Zone 1, II 3G Ex for Zone 2 in gas atmospheres; II 2D / II 3D for dusts).
What does "fire-safe" mean for a valve and which standard applies?
A fire-safe valve is certified to maintain external sealing and shutoff integrity even after exposure to external flame. It is a frequent requirement in ATEX classified zones, oil & gas, refining and anywhere a line fire could propagate through a leaking valve. Test standards: API 607 (eighth edition, for soft-seated ball valves) — the valve is exposed to flame at ~750°C for 30 minutes; after the test it must maintain internal sealing within acceptable limits and still be operable. API 6FA and ISO 10497 for heavy-duty valves. Fire-safe construction includes secondary metal seats activated after PTFE damage, graphite stem packing (resistant beyond 1,000°C), and anti-static device to prevent electrostatic sparks. All Ribel valves for hazardous gas service and ATEX are fire-safe API 607 as standard with individual certificate.
What anti-static must ATEX valves have?
In explosive atmospheres, an electrostatic spark generated by friction between ball, stem and body during operation can ignite combustion — particularly critical for hydrogen (minimum ignition energy 0.02 mJ, the lowest of any industrial gas). This is why ATEX valves require an anti-static device certified per BS 5146-1 and ISO 7121: a series of springs and contacts in stainless steel or nickel-base alloys that ensure electrical continuity between ball, stem and body, with measured resistance < 10 Ω. The body must in turn be earthed to the plant. The anti-static test is individual on each valve, documented with test certificate. Roffia supplies exclusively valves with certified anti-static device for ATEX zone and hazardous gas applications.
Which valve types are required in ATEX zones?
The most requested types in ATEX classified zones are: (1) Fire-safe anti-static ball valves for on-off shutoff — see ball valves with pure PTFE or metal-to-metal seats, anti-static, fire-safe API 607, pneumatic actuator (intrinsically safe) or ATEX electric. (2) PED safety valves for overpressure protection — see safety valves. (3) Bellow seal valves for toxic fluids/hydrocarbons with TA-Luft zero emissions — see bellow seal valves. (4) Butterfly valves for large diameter lines (DN >300) with metal-to-metal fire-safe seats. (5) Check valves swing or dual-plate wafer for backflow prevention. (6) Emergency shutdown valves motorized (ESD valves) with ATEX electric actuators and spring return for closure on blackout. All types must have materials and seals compatible with the specific fluid and operating environment.
In which sectors are ATEX valves required?
ATEX valves are mandatory in all sectors where potentially explosive atmospheres exist: (1) Oil & Gas — refining, hydrocarbon distribution, LPG/LNG, pumping stations. (2) Hydrogen — production, distribution, HRS 350/700 bar, ammonia, H2-methane blending. (3) Biogas and biomethane — digesters, upgrading, grid injection (Zone 1 in many points). (4) Chemical-pharmaceutical — flammable solvents, explosive dusts (Zone 20-22), API production. (5) Mining and extraction — firedamp, coal dust. (6) Painting — solvent vapors in paint booths. (7) Distilleries and food — ethanol vapors in wineries and distilleries, explosive flour dusts (Zone 22). (8) Waste management — landfills, biogas from urban waste.
Does Roffia supply ATEX certified valves with complete dossier?
Yes. All Roffia valves for ATEX classified zones are supplied with: (1) CE marking for the valve (PED) and CE marking + Ex symbol with certification code for electrical accessories (typical II 2G Ex db IIC T6 Gb for Zone 1 hydrogen); (2) individual fire-safe API 607 certificate for each valve; (3) individual anti-static test certificate BS 5146 with measured resistance value; (4) material MTRs 3.1 with heat traceability, 3.2 on request; (5) ATEX EU declaration of conformity for electrical accessories; (6) ATEX installation and maintenance manual with instructions for installation in classified zone; (7) specific marking on valve body and accessories (II 2G Ex for Zone 1 gas, II 3G for Zone 2). The dossier is formatted for HSE, INAIL audits and third-party inspections. For special applications (HRS H2, refineries, oil & gas offshore) we also provide commissioning support with site presence and integrated system documentation.

ATEX valves: compliant selection and supply

Send us service data (fluid, P, T, ATEX zone classification, applicable standards). We select fire-safe valve + Ex electrical accessories and supply complete dossier for HSE, INAIL audits and inspections.