Pure steam for pharmaceutical, biotech and food

Spirax Sarco clean steam systems: CSM generators, lines in AISI 316L electropolished Ra ≤ 0.4 µm, EHEDG / ASME BPE sanitary valves, Tri-Clamp and DIN 11864 connections. For SIP sterilization, clean room humidification, pharmaceutical/biotech process. IQ/OQ/PQ validation pack on request.

Pure steam: pharmaceutical-grade steam

Pure steam (clean steam) is a steam category technically separate from industrial steam: produced from high-quality water (WFI or Purified Water PW), in dedicated generators, distributed through lines in AISI 316L electropolished stainless steel with Ra ≤ 0.4 µm finish and sanitary connections without dead zones. It is used in all applications where steam comes into direct contact with pharmaceutical, biotech or food product: SIP sterilization of reactors, GMP clean room humidification, WFI injection, sterile heat exchanger heating.

Regulation is very strict: EU GMP Annex 1 and Annex 15, FDA cGMP 21 CFR Part 211, USP <1231>, ASME BPE (Bioprocessing Equipment), EHEDG Doc 35. Compliance requires not only correct materials and finishes, but also a complete validation pack dossier (URS, FAT, SAT, IQ, OQ, PQ) and complete lot traceability for every component in line.

Roffia distributes in Italy the Spirax Sarco range of clean steam systems: CSM series generators (50-5,000 kg/h), sanitary diaphragm and ball valves, sanitary reducers, dedicated traps, instrumentation (temperature, pressure, conductivity probes). We also supply sanitary fittings in 316L electropolished, project support for SIP lines and validation dossier. See also food sanitary fittings and the chemical-pharmaceutical sector.

Components of a pure steam system

Clean steam generator

Spirax Sarco CSM series — heat exchange generators (industrial steam → pure steam) or electric. 316L electropolished construction, ASME BPE compliant. Capacity 50-5,000 kg/h. Integrated instrumentation: conductivity, temperature, pressure, NCG. Complete IQ/OQ/PQ validation pack.

Sanitary diaphragm valves

Diaphragm valves with pure PTFE or EPDM diaphragm, 316L electropolished body, Tri-Clamp/DIN 11864 connections. Zero dead zones, ideal for clean steam shutoff and regulation. Compatible with solenoid valves for SIP control.

316L electropolished lines

Piping and fittings in AISI 316L with internal finish Ra ≤ 0.4 µm, MTR 3.1 certified, controlled Delta Ferrite. Tri-Clamp connections (DIN 32676/ASME BPE), automatic orbital welds with weld dossier for each joint.

Sanitary instrumentation

Sanitary PT100 temperature probes, pressure transmitters with flush diaphragm, conductivity probes for feed water quality, NCG sensors for SIP cycle monitoring. Tri-Clamp connections and PG inlets for clean room compatible cabling.

Sanitary reducers and regulators

Pressure reducers in sanitary 316L electropolished version for clean steam reduction stations to end-uses. Pilot-operated or diaphragm, with fine regulation.

Dedicated steam traps

Condensate traps in sanitary version for clean steam lines: float and thermodynamic types in 316L electropolished. SIP cycle drainage and protect end-uses from condensate accumulation.

Typical applications

SIP Sterilization (Steam in Place)

In-line sterilization of reactors, fermenters, piping and exchangers at saturated temperature 121°C for 15-30 minutes. All steam must be clean to avoid product contamination. PLC-controlled automated sequence with temperature and exposure time monitoring.

GMP clean room humidification

Pure steam injection in clean room HVAC to maintain controlled relative humidity (40-60% RH) without contaminating HEPA-filtered air. Critical in GMP A/B classes for aseptic production.

WFI injection

Direct or via heat exchanger to produce hot WFI (75-85°C) for sterile processes: rinsing, formulation, injectables filling. Complete traceability of every batch.

Sterile heat exchanger heating

For pharmaceutical/biotech product heating in exchangers where cross-contamination risk requires highest-quality steam also from service side. Common in formulation/filling.

Related components

Domande frequenti

What is pure steam (clean steam) and how does it differ from industrial steam?
Pure steam (clean steam) is steam produced from highest-quality water (Water for Injection WFI or Purified Water PW) and generated in dedicated generators with sanitary materials and finishes. It differs from industrial steam by: (1) materials — generator, distribution and end-uses in AISI 316L electropolished Ra ≤ 0.4 µm (vs cast iron/carbon steel of industrial steam); (2) water quality — WFI compliant USP/EP/JP, conductivity <1.3 µS/cm at 25°C, endotoxins <0.25 EU/ml (vs industrial boiler treated water with TDS 2,000-5,000 ppm); (3) no chemical additives — no filming amines or alkali treatment (present in industrial steam for corrosion protection); (4) sanitary connections — Tri-Clamp, DIN 11851, DIN 11864 (vs ANSI/EN flanges); (5) validation certification — IQ/OQ/PQ, GMP design, validation pack dossier. It is used for SIP sterilization (Steam in Place), clean room humidification, direct product-contact heating in pharmaceutical, biotech and high-end food.
When is pure steam mandatory?
Pure steam is mandatory in all applications in direct contact with the final pharmaceutical/biotech product or with surfaces in product contact. Specific cases: (1) SIP Sterilization (Steam in Place) — in-line sterilization of reactors, fermenters, piping, valves, exchangers entering contact with active pharmaceutical ingredients. All steam must be clean to avoid product contamination. (2) Steam injection in Water for Injection (WFI) in injectable, biological, vaccine production processes. (3) Clean room humidification ISO 7 class and higher (GMP grade A, B). (4) Sterile heat exchanger heating where any microporosity could cause cross-side contamination. (5) High-value food industry — food production with steam-product contact (injection cooking, top-tier UHT dairy sterilization, infant formula production). Requirements are codified in EMA/FDA cGMP, USP <1231>, EHEDG Doc 35, ASME BPE (Bioprocessing Equipment).
How is pure steam produced? Clean steam generators
Pure steam is produced by dedicated clean steam generators (separate from the plant industrial steam). Technologies are: (1) Thermal gradient generators — industrial steam feeds a heat exchanger that vaporizes WFI/PW water: produced steam is clean because it does not contain primary additives. It is the most common technology in pharmaceutical. (2) Electric generators — direct heating via stainless steel resistors immersed in WFI water: total absence of cross-contamination, higher energy cost. (3) Multi-effect generators for combined WFI + clean steam production (distillation technology). Spirax Sarco CSM and CleanSteam series clean steam generators cover production from 50 to 5,000 kg/h, with complete validation pack dossier (URS, IQ, OQ, PQ docs). Roffia distributes and supports pharmaceutical sterilization projects with generator + clean steam line sizing in 316L electropolished + sanitary valves + instrumentation.
Which materials and connections are required for pure steam lines?
The reference standard is ASME BPE (Bioprocessing Equipment) and EHEDG (European Hygienic Engineering & Design Group). Key requirements: (1) Materials — exclusively AISI 316L with controlled Delta Ferrite (<1%), forged or drawn pipe without longitudinal welds, MTR 3.1 certified with specific chemical composition (low S for weldability). (2) Surface finish — Ra ≤ 0.4 µm (16 µin) electropolished on all surfaces in steam contact. The finish reduces microorganism adhesion and residues, and facilitates CIP cleaning. (3) Connections — exclusively sanitary without dead-zone gaskets: Tri-Clamp (DIN 32676 / ASME BPE) for removable, orbital welding for permanent joints, DIN 11864 aseptic for more critical applications. NO BSP/NPT threaded (dead zones), NO standard ANSI/EN flanges (exposed gaskets). (4) Geometry — no "dead legs" longer than 2× pipe diameter (stagnant zones where bacteria proliferate), minimum 1° slopes toward drain for complete drainage. (5) Welds — automatic orbital with weld dossier for each joint.
Which sanitary valves are needed for clean steam lines?
Pure steam line valves must be EHEDG/ASME BPE sanitary: design without dead zones, 316L electropolished materials, Tri-Clamp or DIN 11864 connections, FDA certification for sealing polymers. Main types: (1) Sanitary diaphragm valves — the reference for clean steam: pure PTFE or EPDM diaphragm separates process fluid from actuation mechanism, ensuring zero dead zones and perfect sealing. ITT Pure-Flo, Saunders, Spirax Sarco HV series, GEMÜ 657/658 models. (2) Sanitary ball valves — 316L electropolished ball, pure PTFE seats, Tri-Clamp body. Common in food grade fittings. (3) Sanitary globe valves for fine flow and temperature regulation. (4) Sanitary safety valves for clean steam generator protection. (5) SIP discharge valves dedicated to sterilization cycle, with timed sequence. Roffia supplies the complete range with MTR, FDA polymer certificates, validation pack if requested.
How is a pure steam system validated? IQ OQ PQ
Validation of a pure steam system is mandatory in pharmaceutical per EU GMP Annex 15 and FDA 21 CFR Part 211. The validation pack dossier includes: (1) URS (User Requirement Specification) — user specifications with required steam quality, flow, pressure, served applications. (2) FAT (Factory Acceptance Test) — factory test of generator before shipment. (3) SAT (Site Acceptance Test) — system test on customer site reception. (4) IQ (Installation Qualification) — verification of installation per P&ID, material MTRs, Ra surface finish, instrument calibration. (5) OQ (Operational Qualification) — verification of operation in all operating conditions, steam quality (conductivity, NCG, endotoxins) for each end-use, cycle repeatability. (6) PQ (Performance Qualification) — verification over time (3-6 months) of steam quality stability in real process conditions. USP <1231> defines quality parameters to verify: feed water conductivity, condensate conductivity, NCG (non-condensable gas), steam dryness, sterilization temperatures, residual moisture. Roffia supports the validation pack dossier collaborating with GMP consultants and provides FDA-compliant formatted documentation.

Pure steam project: sizing and validation pack

Send us process data (required clean steam flow, pressure, served end-uses, GMP class, validation requirements). We perform generator + line + sanitary valve sizing and provide IQ/OQ/PQ validation pack dossier to support GMP qualification.

Privacy Policy Cookie Policy